Well I have kept my mouth shut for a while, but I am outraged about this New York 'gay marriage' thing. Remember what happened in Florida? In New Orleans? In California? Is that kind of disaster headed for NY?
If my dreams amount to anything, I have seen back to back 'natural' disasters. I have seen New York City and Rochester in ruins. I have seen the beginnings of the 'Second Civil War'. Out of the ashes will come a new government not controlled by special interests, not taking money from the poor and giving it to the rich, a government that is actually 'of the people' not 'of the elite'!
BTW I have a history of accurate dreams, three times i dreamed of a jet crashing into a building, in 1998 I wrote down that "I saw a plane rocking as if the pilot did not know what he was doing then it turned into a building, debris was falling everywhere and people were running form the debris."
While I am at it here is the solution for the debt crisis:
Just dissolve the USA and then divide it up into three smaller countries. They would be the North, the South and the West. You could call them the Yankee States (YSA) the Confederate States (CFA) and the Western States (WSA). Since the USA would no longer exist there would be no need to pay back the debt, that country is not there anymore! Otherwise at 1% interest, 14 trillion is 140 billion in interest a year. Do you have that kind of money? What if that climbs to 2 or 3%?
Thursday, July 21, 2011
Monday, July 18, 2011
Network wiring issues resolved
Recently I resolved an issue that has been around for years where I work. A year ago when we upgraded the switch in the service department two computers could no longer connect to the network. I chased the problem down to their network cables and we replaced them.
When we moved the shipping computers to building 3, I reused old network cables and they had problems connecting to the network and the entire network had issues (The Netgear firewall called it a ‘UDP Flood’ and tried to shut it down). When I ran new network cables to those offices the problems went away.
When I tried to connect Building 4 to the network once again we had issues and to ‘fix’ it I told the computer to only connect at 10 Megs (Not the normal 100 megs/second) and the problems appeared to go away. The correct solution would have been to run a new network cable to building 4 but that would take too much time, because it is a buried cable! In an attempt to make a quick fix I tried just changing the connectors on the existing cable and that fixed the problem!
After studying the faulty connectors I saw that two wires were not in their correct position within the plugs. I have since looked at other connectors where I work and have confirmed that some of the network connectors have their wires in the wrong positions. I have used the ‘568b’ network standard for years and it supports up to 1 gig networking. The main offices are all connected at 1 gig. In the future any network cable that I see that does not conform to either 568a or 568b will be replaced!
Back when I was first running network wires I was told that “any order will work” as long as both ends of the cable are done the same. That was actually true back then but I insisted on finding out what was the correct standard and on only following that standard. To connect reliably at 100 mps requires the correct order, and 1 gig will not work at all without the correct order of the wires.
This is one of the faulty connectors, the blue pair should be in the center, surrounded by the Green or Orange pair.
Thursday, July 7, 2011
QSC 1400 Amplifier repair
I recently purchased a non working QSC 1400 amplifier. A few seconds after being powered on the clipping light comes on. I downloaded the schematic and started checking voltages. The +15 and -15 volt power in one channel measured at pins 4 and 8 of the op amp was only +9 and -15 volts. I traced out the power and found +9 at one end and 0 volts at the other end of a 3.9 volt zener diode.
This picture shows the location of the zener in the schematic;
here is the location on the circuit board:
This picture shows the location of the zener in the schematic;
here is the location on the circuit board:
Subscribe to:
Posts (Atom)